Servicing Townsville, Mt Isa, Mackay, Rockhampton, Longreach and more.

Book a free quote

Energex

 

  • EM1000 Single Phase - Import/Export Meter

This meter is single phase import/export meter. The display alternates form positive to negative, reading as follows:

    Positive Display – Shows accumulated imported energy to the customer from the Network
       
    Negative Display – Shows accumulated exported energy from the customer to the Network

General Information

The Scroll button can be used to move to the next display or the display will automatically scroll approximately every 5 seconds.

The red LED that is above the 1 Wh/imp is an indication of power consumption. As your premises imports power, the meter outputs a pulse that equals 1Wh of energy consumed. The LED will flash fast or slow, depending on the load being drawn from the network. Every 1000 pulses the meter will increment 1 kWh.

 

  • EM1200 Single Phase - Import/Export Meter With Load Control

This meter is single phase import/export meter with load control e.g. hot water. The display alternates, reading as follows:

    01 Display – Shows accumulated import energy to the customer from the Network
       
    30 Display - Shows accumulated imported controlled energy to the customer from the network.
       
    40 display - shows accumulated exported energy from the customer to network.

General Information:

The scroll button can be used to move to the next display or the display will automatically scroll approximately every 5 seconds.

The LED’s are indicators for certain application of the meter.  The LED;s in the top corner, (orange & green) are indicators that illuminate when the controlled tariff load relay is on.

The red LED that is above the 1 Wh/imp is an indication of power consumption. As your premises imports power, the meter outputs a pulse that equals 1Kwh of energy consumed. The LED will flash fast or slow, depending on the load being drawn from the network. Every 1000 pulses the meter will increment 1 kWh.

 

  • EDMI ATLAS – Polyphase Import/Export Meter

This meter is polyphase import/export meter. The display alternates, reading as follows:

    001 Display – Shows total (screens 005+010+020) accumulated import energy to the customer from the Network.
       
    005 Display – Shows accumulated import energy to the customer form the Network between 7am -9pm Monday to Friday.
       
    010 Display - Shows accumulated import energy to  the customer from the Network between 9pm-11pm Monday to Friday
       
    020 Display – Shows accumulated import energy to the customer from the network at all other times.
       
    040 Display – Shows exported energy from the customer to the Network.

General Information:

The Display Select button can be used to move to the next display or the display will automatically scroll approximately every 5 seconds.

The light below the battery fail is associated with the PO3 modem reset and may flash from time to time. This is not a fault but a correct operation.

Ergon Energy

 

  • EM1200 or EM1210 – Single Phase on a Primary Tariff (Tariff 22/62)

The digital display has two sections, the Display ID (Code) and the Dislay Data (Actual Reading).

 

The meter will scroll through the Display IDs and Display Data in the order listed in the following table. It is not necessary to push any buttons on the meter to obtain the readings. A test screen is displayed initially to ensure the digital display is working correctly. It will show as a series of 8s in both the Display ID and Display Data. 

Display ID 07 records energy that is exported back into the grid. Solar energy generated will be used by appliances connected to the primary tariff with any excess generation over what is used being recorded on an instantaneous basis on display ID 07.

Display Data Display ID Explanation of reading
Display Test 88 The test displays first as a series of 8s
Date 02 The present date
Time 03 The present time
Rate A kWh Element 1 (Day)
*Only applicable if primary tariff is time of use. E.g. T62 or T22 
04* Energy (kWh) used from grid 7am - 9pm Mon-Fri High Rate
Rate C kWh Elements 1 (Night)
*Only applicable if primary tariff is time of use. E.g. T62 or T22
05* Energy (kWh) used from grid 9pm - 7am Mon - Fri & all weekend - Low rate
Total Import kWh Ellement 1 06 Energy (kWh) used from the grid on primary tariff (e.g. Tariff 11) Sum of 04 & 05 if applicable.
Total Export kWh Element 1 & Element 2 07 Excess energy (kWh) sent back to the grid (Occurs when appliance usage is less than energy generated by the solar panels)
Total Import kWh Element 2 09 Energy (kWh) used on secondary tariff (i.e.Tariff 31 or 33)
Program ID 10 Meter program number - Ergon Energy use only

This page is not intended to provide advice on your personal electricity consumption but should only be used as a guide on how to read your EM1200 or EM1210 meter.

If you have any queries please do not hesitate to contact Ergon Energy Customer Service on 13 10 46.

 

  • Q4 Meter – Two or Three Phase

 

The meter will scroll through the Display IDs and Display Data in the order listed in the following table. It is not necessary to push any buttons on the meter to obtain the readings. A test screen is displayed initially to ensure the digital display is working correctly. It will show as a series of 8s in both the Display ID and Display Data.

Display ID 114 records energy that is exported back into the grid. Solar energy generated will be used by appliances connected to the primary tariff with any excess generation over what is used being recorded on an instantaneous basis on display ID 114.

Display Date Display ID Explanantion of reading
Display Test 888 The test displays first as a series of 8s
Date 001 The present date
Time 002 The present time
Total kWh 003 Total energy (kWh) used from the grid. Equals sum of 004, 005 & 006
Rate A kWh (Day) 004 Energy (kWh) used from the grid between 7 am - 9pm Monday - Friday
Rate B kWh (Shoulder) 005 Energy (kWh) used from the grid between 9pm - 11pm Monday - Friday
Rate C kWh (Night) 006 Energy (kWh) used from the grid at all other times
Previous Cumulative kW 011 Previous Demand - Ergon Use Only
Current Cumulative kW 012 Current Demand - Billing use for Demand Tariffs
Current Maximum kW 013 Highest Maximum Demand recorded since the last reset - Ergon Use Only
Demand Reset Count 040 Number of Times Demand reset - Ergon Use Only
Program ID 042 Meter Program Number - Ergon Use Only
Total kWh Export 114 Total energy (kWh) sent back to the grid. Equals sum of Sum of 115116 & 117
Rate A kWh Export 115 Energy (kWh) sent back to the grid between 7am - 9pm Monday - Friday
Rate B kWh Export 116 Energy (kWh) sent back to the grid between 9m -  11pm Monday - Friday
Rate C kWh Export 117 Energy (kWh) sent back to the grid at all other times

This page is not intended to provide advice on your personal electricity consumption but should only be used as a guide on how to read your Q4 meter.

If you have any queries please do not hesitate to contact Ergon Energy Customer Service on 13 10 46.

 

  • MK10 Multiphase

 

The meter will scroll through the Display IDs and Display Data in the order listed in the following table. It is not necessary to push any buttons on the meter to obtain the readings. A test screen is displayed initially to ensure the digital display is working correctly. It will show as a series of 8s in both the Display ID and Display Data.

Display ID 114 records energy that is exported back into the grid. Solar energy generated will be used by appliances connected to the primary tariff with any excess generation over what is used being recorded on an instantaneous basis on display ID 114.

Display Data Display ID Explanantion of reading
Display Test  888 The test displays first as a series of 8s
Date  001 The present date
Time  002 The present time
Total kWh  003 Total energy (kWh) used from the grid. Equals sum of 004, 005 & 006
Rate A kWh (Day)   004 Energy (kWh) used from the grid between 7am - 9pm Monday - Friday
Rate B kWh (Shoulder)  005 Energy (kWh) used from the grid between 9pm -11pm Monday - Friday
Rate C kWh (Night)  006 Energy (kWh) used from the grid at all other times
Previous Cumulative kW  011 Previous Demand - Ergon Use Only
Current Cumulative kW  012 Current Demand - Billing use for Demand Tariffs
Current Maximum kW  013 Highest Maximum Demand recorded since last reset - Ergon Use Only
Demand Reset Count  040 Number of Demand reset - Ergon Use Only
Program ID  042 Meter program number - Ergon Use Only
Total kWh Export  114 Total energy (kWh) sent back to the grid. Equals sum of Sum 115, 116 & 117
Rate A kWh Export  115 Energy (kWh) sent back to the grid between 7am - 9pm Monday - Friday
Rate B kWh Export  116 Energy (kWh) sent back to the grid between 9pm - 11pm Monday - Friday
Rate C kwh Export  117 Energy (kWh) sent back to the grid at all other times

This page is not intended to provide advice on your personal electricity consumption but should only be used as a guide on how to read your MK10 meter.

If you have any queries please do not hesitate to contact Ergon Energy Customer Service on 13 10 46.